Line 18: Line 18:
   - Reassemble instrument carrier   - Reassemble instrument carrier
  
-{{ :tacho_close.jpg?400 |}}+{{ speedpuls:tacho_close.jpg?400 |}}
  
  
Line 25: Line 25:
 Optionally the output level can be adjusted to 12V (e.g. for TDI control units). Connect the open solder bridge for this purpose. Optionally the output level can be adjusted to 12V (e.g. for TDI control units). Connect the open solder bridge for this purpose.
  
 +{{ speedpuls:12v-variante.jpg?400 |}}
 +
 +
 +===== Connection =====
 +
 +
 +==== Assignment ====
 +
 +
 +^ Color ^ Function ^
 +| Red | Power supply 12V |
 +| Black | Ground | 
 +| White | Signal |
 +
 +==== Fuse ====
 +
 +In itself the Speedpuls is short circuit proof. However, there is a possibility that the connection cable could trigger a short circuit due to a defect.
 +Therefore, the Speedpuls must be protected by a fuse.
 +
 +If the power supply of the Speedpuls is realized via a control unit, then it should be ensured that the control unit is fused accordingly.
 +
 +No matter which voltage source is used, it must be ensured that a suitable fuse is used.
 +
 +It is recommended to use a fuse at the power supply. Otherwise there is a risk of damaging the control unit in case of a short circuit. The fuse should be placed as close as possible to the voltage source. 
 +
 +
 +
 +The Speedpuls can also be connected with its power supply directly to the fuse box.
 +
 +Suitable slots would be:
 +
 +^ Slot ^ Fuse ^ Terminal ^ Description ^ 
 +| G3 | S12 (20A) | terminal X (ignition plus, but relieved at starter) | supply plus for air conditioning |
 +| G2 | S18 (10A) | terminal 15 (ignition plus) | supply plus for GRA (cruise control) |
 +
 +
 +
 +==== Unsuitable voltage sources ====
 +
 +Connecting the speed pulse directly to the battery (terminal 30) is unsuitable.
 +Even if the current demand is in the mA range, this current is permanently drawn at terminal 30. Even if no signal is detected.
 +
 +The speedpulse has no disconnection here.
 +
 +
 +===== Older documents =====
 +
 +For historical reasons, the old documentation is still available here.
 +
 +ATTENTION: These are no longer maintained!
 +
 +
 +Short manual:
 +
 +{{ :speedpuls:kurzanleitung.pdf?linkonly }}
 +
 +
 +Detailed installation instructions
 +
 +{{ :speedpuls:einbauanleitung.pdf?linkonly }}
 +
 +
 +
 +
 +----
  
speedpuls/speedpuls_en.1674237296.txt.gz · Last modified: 2024/04/05 21:19 (external edit)